The Kodak i600 Series Scanners window provides access to your Imprinter tab along with the check box for enabling the batch counter For more information on your scanner, consult your scanner User's Guide. For general information on image addressing, click here.
Imprinter tab
Enable imprinter - check this box to enable the printer and make the following options available.
Counter - this is the document count for the scan session. This value is incremented sequentially by the scanner and returned in the image header.
Counter length - allows you to configure the length of the counter from 1 - 9. However, if for example, you only have six characters left in the print string, then the length would be limited to 6.
Counter format - allows you to configure the format of the counter when the width of the value is less than the field width (the examples indicate a field length of 3 and the counter at 4). Select one of the following formats from the drop-down list:
-
Display leading zeroes "004"
-
Do Not Display: "4"
-
Display As Spaces: " 4"
Date Delimiter-Date Delimiter- select a separator setting from the drop-down list:None, Forward Slash(2006/08/24),Hyphen (2006-08-24),Period(2006.08.24), orBlank(2006 08 24).
Font - from the drop-down list, select Large comic, Large cine, Large comic 180, Large cine 180, Small comic, Small cine, Small comic 180, or Small cine 180.
Position - select a value from 0.35 to 33.5 inches to determine how far the printed information will appear from the leading edge of the document.
-
Printing automatically stops 6.3 mm (1/4-inch) from the trailing edge of the document even if the information has not been completely printed.
-
The horizontal print position is set manually on the scanner. See the User’s Guide for information on changing the horizontal print position.
Message Configuration - displays the Message Configuration dialog box for your scanner. This dialog box allows you to specify custom text to be included in your print string. A maximum of 20 characters is allowed. You can have up to six unique messages per string.
Print string - enter a print string or click Setup to open the Formula Configuration dialog box and set up your print string using predefined values.
New batch starts with counter equal to - enable the checkbox for this feature, then enter a starting number in the text field.
OK - saves your settings and closes the dialog box.